POLLYCOTE APPLICATION INSTRUCTIONS About Us | Contact Us | Home  

 

SURFACE PREPARATION Click to view print version

FACTORY COATINGS

(a) Remove all loose coating using a knife,scraper or copper headed hammer. Avoid damage to the pipeline metal.
(b) Remove all dirt, soil or wash by wire brush or wiping for at least l5Omm, on both ends of pipe.
(c) Remove any oil or grease from the p.e. or PVC coating with xylene (if pipes have plastic coating).
(d) Lightly abrade p.e. coatings with a wire brush or coarse abrasive paper.
(e) Bevel the edges of previous coatings using a heated scraper to form a 50 mm bevel, if previous coating is thick coating system(e.g. Coal Tar Enamel coating).
METAL
(a) Remove any oil or grease with xylene. Remove any metal burrs and weld spatter.
(b) Grit blast to meet B54232 2nd quality (SIS55900 Sa 21/2) or wire brush to meet SIS055900 St2 or 3
(c) Remove any abrasion debris.
(d) Apply primer evenly by brush immediately following the abrasive cleaning. Avoid contamination of the surface by maintaining an adequate distance between blasting and priming.
PRIMING
(a) Stir the primer and transfer to a clean wide-aperture container. Use only clean dry brushes.
(b) Apply evenly ensuring complete cover, particularly around weld beads.
(c) Let primer dry, to a touch dry condition (check with knuckles).
(d) Re-seal containers when not in use.
WRAPPING
(a) Wrapping should not commence until the primer surface has become touch dry. The primer surface must be uncontaminated.
(b) Apply strips of tape l00 mm wide along the weld beads and press firmly into the bend profile.
(c) Peel back 15 to 30cm of the release interleave and apply the tape, adhesive face to the pipe. The angle of the tape to the pipe must be such as to produce the specified overlap. Ensure an overlap area of at least 75mm on the factory coating, and an overlap of 25mm on normal new pipe coating.
(d) Apply only sufficient tension to ensure good conformation,avoiding air pockets and bridging.
(e) Ensure overlap areas of at least 150mm when splicing tapes.
(f) Backfill with care. Avoid use of rocky or agglomerated backfill or use additional outerwrap protection.
GENERAL
(a) Surface preparation, priming or wrapping should not take place when the substrate is wet. Do not carry outwork when the surface temperature is less than 30C above the dew point.
(b) Tapes should be stored at temperatures between 100C and 250C for at least two hours before application when ambient temperatures are below 100C.
(c) All sources of ignition must be extinguished or removed before carrying out priming operations. Adequate ventilation must also be ensured.
(d) Store the tapes at temperatures not exceeding 400C and avoid excessive stacking of loads.

During application it is important to maintain even tension during the wrapping whilst controlling the overlap to prevent air entrapment leading to corrosion at a later stage. The tapes are best applied by machine, either hand powered for small runs or mechanically propelled for longer runs or by hand for joints or small runs. The Pollycote tapes are normally supplied in 10m lengths for 1500 and in 15m lengths for the others. For machine operations these lengths are increased to suit the project and reduce the number of roll changes.

 

[ Pollycote | Politt | Pollatum | Mastics | Rockshields | Pollyseal | Inspection and Wrapping Machines ]

P o l l y a i m
313-B, Ballards Lane, London N12 8LY, United Kingdom
Tel: +44 7518921274 Email: info@pollyaim.co.uk, Visit us at www.pollyaim-ltd.com

Pollycote, Pollyseal, Politt & Pollatum are trademarks of Pollyaim Ltd. All rights reserved, Copy rights 2016